The Department (NYSDEC) requests releases from the FFMP2017 Thermal Mitigation Bank from Cannonsville, Pepacton, and Neversink due to the extremely warm weather.
We request a 300 cfs increase to the release from Cannonsville Reservoir, a 25 cfs increase at Pepacton Reservoir and a 25 cfs increase at Neversink Reservoir.
Cannonsville Reservoir
Friday, July 19th, 2019
3:00 PM 500 cfs to 650 cfs (+150 cfs)
4:00 PM 650 cfs to 800 cfs (+150 cfs)
Maintain 800 cfs until 12:01 PM Sunday
Sunday, July 21st, 2019
12:01 PM 800 cfs to 750 cfs (-50 cfs)
2:00 PM 750 cfs to 700 cfs (-50 cfs)
4:00 PM 700 cfs to 650 cfs (-50 cfs)
6:00 PM 650 cfs to 600 cfs (-50 cfs)
8:00 PM 600 cfs to 550 cfs (-50 cfs)
10:00 PM 550 cfs to 500 cfs (-50 cfs)
Pepacton Reservoir
Friday, July 19th, 2019
4:00 PM 150 cfs to 175 cfs (+25 cfs)
Maintain 175 cfs until 4:00 PM Sunday
Sunday, July 21st, 2019
4:00 PM 175 cfs to 150 cfs (-25 cfs)
Neversink Reservoir
Friday, July 19th, 2019
4:00 PM 115 cfs to 140 cfs (+25 cfs)
Maintain 140 cfs until 4:00 PM Sunday
Sunday, July 21st, 2019
4:00 PM 140 cfs to 115 cfs (-25 cfs)
When complete, please return to ordinary operations.
Thank you,
Brenan
Brenan Tarrier, P.E.
Professional Engineer 1, Division of Water
New York State Department of Environmental Conservation
625 Broadway - 4th Floor, Albany, NY 12233
P: 518-402-8157 | F: 518-402-8082 | brenan.tarrier@dec.ny.gov